ANN-BASED SUPERVISORY CONTROL OF VEHICLE-TO-GRID TECHNOLOGY IN A MICROGRID USING DC FAST CHARGING ARCHITECTURE
DOI:
https://doi.org/10.64751/Abstract
Electric vehicle (EV) batteries can act as energy storage in micro-grids by charging when there is surplus generation (grid-to-vehicle, G2V) and returning energy when it is needed (vehicle-to-grid, V2G). Mohammed Shakeel and Malik proposed a DC fast-charging station for V2G in a grid-connected microgrid, in which four EVs and a 50 kW photovoltaic array share a 1.5 kV DC bus that is connected to the micro-grid through a 250 kVA grid-connected inverter with an LCL filter. In that work the battery chargers and the inverter use fixed-gain proportional–integral (PI) controllers, which produce DC-bus voltage spikes of 40–65 V and battery-current overshoot of about 11 % whenever an EV changes mode. This thesis replaces every PI regulator of the station — the constant-current loops of the off-board chargers and the dq current and DC-voltage loops of the inverter — with an artificial neural network (ANN) controller. Each ANN is a 3–10–1 multilayer perceptron whose inputs are the error, its integral and its derivative, and it slots into the original control structure without changing the feed-forward, decoupling or modulation stages. A two-stage training method is proposed: the networks are first fitted to the PI law with the Levenberg–Marquardt algorithm, giving a stable starting point, and are then optimised in closed loop with an evolution strategy on a station model that includes computation delay and sensor noise. A PI controller re-tuned on the same objective is used as an additional benchmark. Simulation studies covering the base-paper V2G–G2V scenario, PV variation, four simultaneous EVs, parameter variation, grid voltage sag, power quality and sensor noise show that, compared with the basepaper PI, the ANN reduces the DC-bus voltage deviation by 20–29 %, roughly halves the DC-bus settling time, lowers the ITAE by 64 %, cuts battery-current overshoot to 2–5 % and reduces inverter modulation noise by 60 %. The optimised PI benchmark achieves nearly the same dynamics, so the benefit specific to the ANN structure is modest. The ANN also gives higher grid-current THD than the base PI (1.08 % against 0.74 % under base-paper conditions, but 5.82 % against 4.24 % with dead time) and loses part of its advantage under combined parameter variation. These limitations, and the remedies proposed for them, are discussed.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 American Journal of Management and IOT Medical Computing

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.







